-40%

MS400 Patient Simulator ECG Multi-parameter Monitor Touch Screen Fedex USA

$ 210.67

Availability: 100 in stock
  • Restocking Fee: No
  • Brand: CONTEC
  • Return shipping will be paid by: Buyer
  • Model: MS400
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Condition: New
  • Item must be returned within: 60 Days
  • MPN: 69450401

    Description

    MS400 patient simulator
    Description
    Introduction
    MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement. It can check the monitor rapidly near the bed, also can test the quality warranty of ECG equipment, monitor and remote therapy equipment, At the same time, it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
    ■3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
    ■Display the output waveforms synchronously, which is convenient for user to
    compare with the   test equipment.
    ■It integrates the functions of SD socket interface, user can output the
    custom waveform by this   device.
    ■Built-in templates list to provide the waveform that is expressed by each
    preset sequence   number,which is convenient for searching.
    ■Two operation interfaces:Chinese and English.
    ■Operate with keystroke and touch-screen expediently and rapidly.
    ■Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
    ■Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
    ECG/Arrhythmia
    ECG
    ■Conventional: All leads have the same voltage with the II-lead as the reference
    ■Amplitude: 0.5,1.0,1.5 and 2.0mV
    ■The accuracy of Amplitude: ±2%
    ■ECG Rate:
    15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340      and 350 BPM
    ■ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing
    ■The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV
    ■The default: 80 BPM,1mV
    Arrhythmia
    ■Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia,
    Missed Beat, Atrial
    ■Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
    ■Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular
    Contraction (PVC) 6/min,
    ■PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired
    PVCs, Run 5
    ■PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    ■Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left
    Ventricular Focus
    ■PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early
    Right
    ■Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right
    Ventricular Focus, Multifocal PVC
    ■Conduction Defects: First Degree Heart Block, Second Degree Heart Block,
    Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch
    Block
    ECG Performance Testing
    ■ECG amplitude:0.5,1.0,1.5 and 2.0mV
    ■The accuracy of Amplitude: ±2%
    ■Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms
    ■Square: 0.125 and 2.0 Hz
    ■Triangle: 2.0 and 2.5 Hz
    ■Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz
    ■ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240,
    260, 280, 300,   320, 340 and 350 BPM
    ■The accuracy of ECG Rate: ±1%
    optional function:
    Respiration
    ■Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN
    ■Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    ■Baseline Impedance:500,1000,1500 and 2000
    ■Apnea: 12 s, 22 s, 32 s
    ■ECG simulator with adjustable heart rate/12-lead output
    ■33 kinds of Arrhythmia waveforms
    ■Pacemaker
    ■Two IBP channels
    ■Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32
    seconds.
    ■Standard ECG calibration
    ■Export square,triangle and sine with adjustable frequency
    IBP
    ■The default: 00/00mmHg
    ■Dynamic IBP
    Channel 1: Artery  120/80mmHg
    Radial 120/80mmHg
    Left Ventricle 120/00mmHg
    Right Ventricle 25/00mmHg
    Channel 2: Artery  120/80mmHg
    Radial 120/80mmHg
    Left Ventricle 120/00mmHg
    Right Atrium 15/10mmHg
    Right Ventricle 25/00mmHg
    Pulmonary Artery 25/10mmHg
    Left Atrium 14/4mmHg
    Static-Pressure Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100, 150, 200 and 250mmHg
    Buy Safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.  If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
    The item is registered on the Australian Register of Therapeutic Goods(ARTG) with the code 197923,
    and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved.
    Payment
    We accept payment by PayPal. PayPal enables you to make payment quickly and securely online.
    1: We accept payment via PayPal.
    2: Please pay the money within 5 days after the auction ended.
    3: Please offer home or mobile phone when the item's Value exceeds 100 (USD, EUR, AUD, GBP) so that we can
    make sure you get the item safely.
    Shipping
    1. Items are dispatched from China with in 48 hours after payment receiced or eCheck cleared.
    2.Please make sure the address and tel number are right,both of the information  is very important for delivery,thank you for your kindly cooperation.
    3.After the shipment,we will add the tracking number on both ebay and paypal  website,you can check it and track it by the number.
    4. Usually we ship this item from China by air small package,it takes about 10-45 days arrive,and we will supply a tracking number to check its state online.
    Terms of Sale
    We offer 60 days return policy. 100% satisfaction is our goal!
    1. All items are brand new, with 2 years warranty.
    2.Client is reaponsible for the custom cleatance and custom duty.
    If any, we will not be responisble for the customs clearance and duty, if you have special requirments for the declaration for your customs office, please contact us before your payment.
    3. Customer is responsible for the returning shipping fee and we will send the replacement after receiving the returned item.
    4.  Your positive feedback will be appreciated very much,  and in any case, please do contact us before leaving nagative feedback or ship the item
    back, we promise we will give you a satisfied answer.
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992
    as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.
    Most of the domestic hospitals are our customers.
    Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
    Contact Us
    Contec Medical Systems---jane
    We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely