PM10MS400 Multi parameter Simulator Patient ECG IBP Resp Temp Simulation
Description
Introduction
Introduction
MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.
Main Performance
■3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.
■Display the output waveforms synchronously, which is convenient for user to
compare with the test equipment.
■It integrates the functions of SD socket interface, user can output the
custom waveform by this device.
■Built-in templates list to provide the waveform that is expressed by each
preset sequence number,which is convenient for searching.
■Two operation interfaces:Chinese and English.
■Operate with keystroke and touch-screen expediently and rapidly.
■Built-in 3.7V/4000mAh(Rechargeable alkaline battery).
■Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
Main Features
1) Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
2) Simulate four-channel IBP data.
3) Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
4) Simulate four kinds of temperature data.
5) Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
6) Simulate standard ECG calibration, adult and pediatric ECG signal.
7) ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
8) Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.
9) Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
10) Optional operation modes: keys and touch screen.
ECG:
Conventional: All leads have the same voltage with the II-lead as the reference
Amplitude: 0.5, 1.0, 1.5 and 2.0mV
ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia:
ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Four IBP Channels:
The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz: press ENTER key to change every time
Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3
Respiration:
Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
Baseline impedance: 500, 1000, 1500, 2000Ω
Apnea: 12 s, 22 s, 32 s
Temperature:
Four temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.
Shipping
1. For your earlier and safer to receive the item, please leave us your detail address and telephone number.
2. Your item will be sent via Air mail within 48 hours after payment is received.
3. As the usual way, buyer is responsible for the duties, taxes or other VAT or extra charges from the import countries.
4.All items will be shipped to buyer's PayPal address. Please confirm your PayPal address is correct before purchase.
International Buyers - Please Note:
? Import duties, taxes are not included in item price or shipping charges. These charges are buyer's responsibility.
? Please check with your country's customs office to determine what these additional cost will be prior to bidding
Terms of Sale
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved
Return - After service
We offer 60 days return policy. 100% satisfaction is our goal!
1.All items are brand new ,with 1 years warranty.
2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the item.
3.We will refund the money to you when we get the return items or replace item for you.
4. All return items must be returned with its original package and accessories. Customer is responsible for shipping charges on returned items.
About Us
Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.
At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
Contact Us
Contact Person:Vivian Zhang
Mobile/ICQ/WhatsApp:+8618617816016
Contec Medical Systems Co.,Ltd, Manufacture
Address(US):1440 Chase Avenue,Elk Grove Village,Illinois 60007 United States